7SD610 Universal Differential Protection Relay

7SD610 Universal Differential Protection Relay

The 7SD610 relay is a differential protection relay suitable for all types of applications and incorporating all those functions required for differential protection of lines, cables, and transformers. Transformers and compensation coils within the differential protection zone are protected by means of integrated functions, which were previously to be found only in transformer differential protection. It is also well-suited for complex applications such as series and parallel compensation of lines and cables.It is designed to provide differential and directional backup protection for all voltage levels and types of networks. The relay features high speed and phase-selective short circuit measurement. The unit is thus suitable for single-phase and three-phase fault clearance.Digital data communication for differential current measurement is effected via fiber-optic cables, networks or pilot wires connections so that the line ends can be quite far apart. The serial protection interface (R2R interface) of the relay can flexibly be adapted to the requirements of all existing communication media. If the communication method is changed, flexible retrofitting of communication modules to the existing configuration is possible.Apart from the main protection function, i.e. the differential protection, the 7SD610 has a full range of configurable emergency and/or backup protection functions such as phase and earth over current protection with directional elements if voltage transformers are connected. Overload, under and over-voltage/frequency and breaker failure protection round off the functional scope of the 7SD610.

Protection Functions

Differential protection for universal use with power lines and cables on all voltage levels with phase-segregated measurement (87L)
Two line ends capability
Suitable for transformers in protected zone (87T)
Restricted earth-fault protection (87N) if a transformer is within the protection zone
Well-suited for serial compensated lines
Two independent differential stages: one stage for sensitive measuring for high resistance faults and one stage for high current faults and fast fault clearance
Breaker-failure protection (50BF)
Phase and earth overcurrent protection with directional element (50, 50N, 51, 51N, 67, 67N)
Phase-selective intertripping (85)
Overload protection (49)
Over/undervoltage protection (59/27)
Over/underfrequency protection (81O/U)
Auto-reclosure single/three-pole (79)
Control functions

Command inputs for control of CB and disconnectors (isolators)
Monitoring functions

Self-supervision of relay and protection data (R2R) communication
Trip circuit supervision (74TC)
8 oscillographic fault records
CT-secondary current supervision
Event logging / fault logging
Switching statistics
Front design

User-friendly local operation
PC front port for relay setting
Function keys and 14 LEDs f. local alarm
Communication interfaces

1 serial protection data (R2R) interface
Front interface for PC connection
System interface
IEC 61850 Ethernet
IEC 60870-5-103 protocol
PROFIBUS-DP, DNP 3.0 and MODBUS
Service / modem interface (rear)
Time synchronization via IRIG-B, DCF77 or system interface