Product

7UM61 Generator And Motor Protection Relay

7UM61 Generator And Motor Protection Relay

The SIPROTEC 4 7UM61 protection relays can do more than just protect. They also offer numerous additional functions. Be it earth faults, short-circuits, overloads, over voltage, over frequency or under frequency, protection relays assure continued operation of power stations.The SIPROTEC 4 7UM61 protection relay is a compact unit which has been specially developed and designed for the protection of small and medium-sized generators.They integrate all the necessary protection functions and are particularly suited for the protection of:-Hydro and pumped-storage generators-Co-generation stations-Private power stations using regenerative energy sources such as wind or biogases-Diesel generator stations-Gas-turbine power stations-Industrial power stations-Conventional steam power stationsThe device can also be used for protecting synchronous and asynchronous motors.The integrated programmable logic functions (continuous function chart CFC) offer the user high flexibility so that adjustments can easily be made to the varying power station requirements, on the basis of special system conditions.The flexible communication interfaces are open for modern communication architectures with the control system.

BASIC VERSION
Stator earth-fault protection

Sensitive earth-fault protection

Stator overload protection

Overcurrent-time protection (either definite-time or inverse-time)

Definite-time overcurrent-time protection, directional

Undervoltage and overvoltage protection

Underfrequency and overfrequency protection

Reverse power protection

Overexcitation protection

External trip coupling

STANDARD VERSION - SCOPE OF BASIC VERSION PLUS
Forward-power protection

Underexcitation protection

Negative-sequence protection

Breaker failure protection

FULL VERSION - SCOPE OF STANDARD VERSION PLUS:
Inadverdent energization protection

100%- stator earth-fault protection with 3rd harmonic

Impedance protection

ASYNCHRONOUS MOTOR - SCOPE OF STANDARD VERSION PLUS
Motor starting time supervision

Restart inhibit (without underexcitation protection)

MONITORING FUNCTIONS
Trip circuit supervision

Fuse failure monitor

Operational measured values V, I, f,…

Every metering value Wp,Wq

Time metering of operation hours

Self-supervision of relay

8 oscillographic fault records

COMMUNICATION INTERFACES
System interface
- IEC 60870-5-103 protocol
- PROFIBUS-DP
- MODBUS RTU
- DNP 3.0

Copyright © 2024 Hi-Tech Electricals. All rights reserved | Developed by : Notion Technologies