7UT613 Differential Protection Relay For Three Winding

7UT613 Differential Protection Relay For Three Winding

The SIPROTEC 7UT613 differential protection relays are used for fast and selective fault clearing of short-circuits in transformers of all voltage levels and also in rotating electric machines like motors and generators, for short lines and busbars.The specific application can be chosen by parameterization. In this way, an optimal adaptation of the relay to the protected object can be achieved.In addition to the differential function, a backup overcurrent protection for 1 winding/ star point is integrated into the relay. Optionally, a low or high-impedance restricted earth fault protection, a negative-sequence protection, and a breaker failure protection can be used.7UT613 features 4 voltage inputs. With this option an overvoltage and under voltage protection are available as well as frequency protection, reverse / forward power protection, fuse failure monitor and overexcitation protection. With external temperature monitoring boxes (thermo-boxes) temperatures can be measured and monitored in the relay. Therefore, complete thermal monitoring of a transformer is possible, e.g. hot-spot calculation of the oil temperature.7UT613 features full coverage of applications without external relays by the option of multiple protection functions e.g. overcurrent protection is available for each winding or measurement location of a transformer. Other functions are available twice: ground-fault differential protection, breaker failure protection, and overload protection. Furthermore, up to 12 user-defined (flexible) protection functions may be activated by the customer with the choice of measured voltages, currents, power and frequency as input variables.The relays provide easy-to-use local control and automation functions. The integrated programmable logic (CFC) allows the users to implement their own functions, e.g. for the automation of switchgear (interlocking). User-defined messages can be generated as well. The flexible communication interfaces are open for modem communication architectures with control system.

FUNCTION OVERVIEW
Differential protection for 2- up to 3-winding transformers (3-/1-phase)

Differential protection for motors and generators

Differential protection for short 2 up to 3 terminal lines

Differential protection for busbars up to 9 feeders (phase-segregated or with summation CT)

PROTECTION FUNCTIONS
Differential protection with phase-segregated measurement

Sensitive measuring for low-fault currents

Fast tripping for high-fault currents

Restraint against inrush of transformer

Phase-/earth overcurrent protection

Overload protection with or without temperature measurement

Negative-sequence protection

Breaker failure protection

Low-or high-impedance restricted earth fault (REF)

Voltage protection functions

CONTROL FUNCTIONS
Commands for control of c.b. and isolators

Control via keyboard, binary inputs, DIGSI 4 or SCADA system

User-defined logic with CFC

MONITORING FUNCTIONS
Self-supervision of the relay

Trip circuit supervision

Oscillographic fault recording

Permanent differential and restraint current measurement, extensive scope of operational values

COMMUNICATION INTERFACES
PC front port for setting with DIGSI 4

System interface IEC 61850 Ethernet - IEC 60870-5-103 protocol - PROFIBUS-FMS/-DP - MODBUS or DNP 3.0

Service interface for DIGSI 4 (modem)/ temperature monitoring (thermo-box)

Time synchronization via IRIG-B/DCF 77